RS2 - Rugged MIPIOS® Unmanaged Ethernet Switch
Technical Data
Switch Fabric Key Features
Eight 10/100Base-T ports at front panel
•
Electrical isolation: 1500Vrms
1 Gigabit uplink port at front panel
Auto-negotiation
High-speed non-blocking, store-and-forward switching
8K MAC address lookup table with automatic learning and aging
QoS (Quality of Service) support with 4 traffic classes (IEEE 802.1p tagged frames)
Layer 2 switching
Back pressure or IEEE802.3x flow control
Automatic MDI/MDI-X crossover (all ports)
TCP/IP (IPv4, IPv6)
Layer 2 Features
Transparent bridging
QoS (DiffServ) and 802.1p traffic prioritization queuing, polishing, shaping
VLAN-aware bridging
Security Features
MAC based and IP based access list (ACL) for traffic filtering
Rate-limiting and storm control to prevent packet flooding from malicious peers
Supported Ethernet Standards
Transparent bridging: IEEE 802.1d, 2004
VLAN: IEEE 802.1q Rev D5.0, 2005
Port based VLANs: IEEE 802.1q Rev D5.0, 2005
Link aggregation: IEEE 802.3ad, 2005
Power over Ethernet support: IEEE 802.1af
Priority based switching: IEEE 802.1p
Power Over Ethernet Features
Power over Ethernet functions on ports 1 and 2
•
PSE (Power Sourcing Equipment) function
•
Supplies one PD class 0 device or two PD class 2 devices (up to 15W total)
Service Interface
M12 connector at front
SPI interface for external SPI programmer
Front I/O
8 Ethernet ports via M12 connectors
Gigabit uplink port
•
8-pin M12 connector, A-coded
1 service interface via M12 connector
2 redundant power inputs via M12 connectors
Link and activity Ethernet status LEDs (2 per channel)
Power over Ethernet status LEDs
Status LEDs for power and reset
Electrical Specifications
Power input
•
Nominal input voltage 24VDC (9 to 36V) or 110VDC (77 to 150V) according to EN50155
•
Two redundant inputs
•
Power-on threshold: 0.7xUn = 16.8V (for 24VDC PSU) or 77V (for 110VDC PSU)
•
Power change-over threshold (when a secondary power source is connected): 12V (for 24VDC PSU) or 66V (for 110VDC PSU) (lower input voltage results in automatic switch to secondary power source)
•
Minimum input voltage when no secondary power source is connected: 9V (for 24VDC PSU) or 66V (for 110VDC PSU)
EN50155 power interruption class S2
Isolation (according to EN50155)
•
Input/output: 1500VDC/1000V eff
•
Input/shield: 1500VDC/1000V eff
•
Output/shield: 1500VDC/1000V eff
•
Ground/shield: 1500VDC/1000V eff
Power consumption: tbd.
MTBF: Approx. 200,000h (tbc.) @ 40°C according to IEC/TR 62380 (RDF 2000)
Mechanical Specifications
Dimensions: 220mm x 130mm x 70mm (without connectors)
Prepared for wall or DIN-rail mounting with special mounting plates (available separately)
Weight: 1.9kg
Environmental Specifications
Temperature range (operation):
•
-40..+70°C (+85°C) with up to 85°C for 10 minutes according to class Tx (EN50155)
•
Airflow: natural convection
Temperature range (storage): -40..+85°C
Relative humidity (operation): max. 95% non-condensing
Relative humidity (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Climatic tests according to EN68068
Shock and vibration tested according to EN61373
IP 67 compliant
Conformal coating on request
Safety
PCBs manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to the following railway standards:
•
EN50121 (radio disturbance)
•
EN61000-4-2 (ESD)
•
EN61000-4-4 (burst)
•
EN61000-4-5 (surge)
Conforming to E1 requirements of the German Federal Motor Transport Authority
Tested according to the following automotive standards:
•
CISPR25/CISPR16 (radiated emission)
•
ISO7637-2 (conducted emission - power line)
•
ISO7637-2 (conductive immunity - power line)
•
ISO7637-3 (capacitive immunity - signal line)
•
ISO11452-2, ISO11452-5 (radiation immunity)
•
ISO10605 (ESD immunity)
•
EN50121 (radio disturbance)